33kv dp structure drawing

300 WILL BE SUPPLIED BY TSSPDCL 22 Supply of 12 Core x 25 Sq. High mast lights 16 M high 2 Nos.


Electrical Ideas Dtr Structure Dp Structure Double Pole Structure Facebook

Poles or Rail pole.

. 2 and 11kV EB post RCC. Boundary Wall 1103 Gates 2. On level ground between structures of the same height this is equal to half the sum of the adjacent spans.

Ds 1250 a 25 ka3s bb vt1 tr inc1 bb vt2 inc 1 dlshad h m ali. Hexagonal screwdriver insert minimum length 140mm for hexagon socket head bolt 10mm. Ds 1250 a 25 ka3s 33 kv cb 1250 a 25 ka3s 33 kv 3pos.

Locations are of PCC. OVERHEAD LINES FOR ROAD CROSSING. Gantry tower is a structure commonly found in electrical substation or transmission line.

Install three phases of isolator on structure parallel to each other couple the pole with coupling pipe link it with operating lever align all the elements in ON. This ensures efficient transmission of power minimizing the power losses. 33kv Double Pole Structure Drawing 225 Book Diagrams.

TRANSFORMERS 3 C 300 XLPE 33 KV CABLE 3 C 300 XLPE 33 KV CABLE 28 nos 1c 630 sqmm XLPE Arm. Besides separation wall are provided in between the transformers and also between the transformer and roads within the substation. The transformer steps down the voltage to 400V 3-phase 4-wire supply.

Spans adjacent to a structure under minimum temperature conditions. SWF 330-SK250 with lamp of Philips or. Locations and 03 cum for stay sets is 28 cum irrespective whether DP.

33KV double bus GIS Switchgear including Bus PT 8 Nos. Topographical Layout and Profile Drawings 34 Annex B Design and Construction Data 43 Annex C Bill of Quantity 53. Design of 33kV switchyard equipment SLD and layout for small hydro-power plant Alternate Hydro Energy Centre Indian Institute of Technology Roorkee.

CONSTRUCTION STANDARD DRAWINGS DIVISION 15. RCC structure Length 2782 m Width 1624 m Height 1200 m Tailrace length 80 m Turbine. Side to protect the sub-station from lightning strokes.

The Fifth Chapter Is Devoted To Winding Diagrams Of DC. 33 kV Double Circuit Transmission Line Project Design Report Of Suri Khola Hydropower Project. As Also Plant And Substation Layout DiagramsMiscellaneous Drawing Like.

B Standard Designs Transmission Lines Type 3TA-1 69. DP structure for 11kV line with 250kVA transformer mounted single incomer cum outgoing. The rate shall include supply and fixing of 250W SV Lamp fitting Cat No.

Channels based on structure. Cables 8 nosPh 4 Neutral 5000A 4P. First I will tell you what is the purpose of the DP structure or distribution transformer structure The function of the DP structure is to step-down the incoming voltage ie of 11 KV to 440 volts three phases or 230 volts single-phase.

REC Power Distribution Company Limited. Line differential relays for remote end with DC-DC converter if required2 Nos. The power factor is corrected here and the voltage is stepped down to 33KV and power is then transferred to distribution system of the grid to.

DOUBLE BREAK Rotating isolator With Earth Switch Application. Whether the jumpers can be used as a Isolation point during outages of 11KV. It is designed to be mounted in horizontal upright position on 2 nos.

Ds 1250 a 25 ka3s 33 kv 3pos. 33 kV 1250 Amp. Our project is to design a 132KV33KV EHV substation where the incoming power is received at 132 KV from a generating station.

739 Ensure the following tools are available and ready by the commencement of work. Cable Pot Head structure- 2 Set 3 Nos per Set SCADA RTU- 1 Set ACDB 1 Set. Ds 25 ka3s v 33000 3 3 110 m 33 kv 3pos.

3C X 185 SQ MM. Architectural Works 21 General 22 Scope of Work 23 Materials 24 Signage. Do this before the installation of the 33KV transformer.

60055 cl1 30 va 5p10 15 va m m 33 kv 3pos. 738 Make sure the transformer room is dirt free and dust free. The 11 kV line is connected to the transformer 11kV 400 V through gang isolator and fuses.

Locations is for 6 guy sets 20 mm Rod of turn buckle x 74 stay-wire 85 kg in wt for each location. The lightning arresters are installed on the HT. Battery charger with DCDB--1 Set.

XLPE CABLE ON DP STRUCTURE PCCPSC POLES UPCL11KV14 39 33-11kV. 1842 Foundations for all Buildings and Structures 1843 Cable Trenches Drawpits and Duct Banks 19 Water Supply Drainage and Disposal 191 Water Storage Tank 192 Drainage and Sewage Disposal 110 Boundary Walls 1101 General 1102. Mounted on H-type pole or 4-pole structure.

It is a combination of two or more legs towers and an overhead beam. To the overhead beam a lifting device is connected. D Substation Standards Ground Cable on Tubular Steel Structures Support Details 21.

SlNo Drawing Description Drawing Number 20 33KV SUB-STATON UPCL33KV20 21 V SHAPED CHANNEL CROSS-ARM SUITABLE FOR 33 KV LINE UPCL33KV21 22 DANGER PLATE UPCL33KV22 23 GUARDING BELOW 33 KV. PCC pedestal etc as per drawing. Name of Item Quantity Estimated unit cost 1 LINE DP SET FOR 33 KV 1214 sets 172769 MT Rs.

Ds 25 ka3s 33 kv 3pos. The details are as under- S. Chapter Vi And Vii Include Drawings Of Transmission And Distribution Line Accessories Supports Etc.

20 Supply of GI structure for 33kv Bay 3 KG 21 Supply of ACSR Conductor Panther. Ds 1250 a 25 ka3s 33 kv cb 1250 a 25 ka3s 33 kv 3pos. Tenders are hereby invited in e-procurement system for purchase of LINE DP SET FOR 33 KV under TN-1555.

Ds 25 ka3s v. Gantries can be constructed to. 1015 Surge Arrestors 138kv 33kv 22 1016 Anti Climbing Device 22 1017 Grounding 22 11 CONDUCTOR ERECTION 23 111 Tensioning of Conductors 23 112 Stringing 23.

18 rows Standard Drawing for 33 KV Single Line Diagram for 33KV Independent Feeder. C Substation Standards Danger Sign for Shunt Capacitors. 33KV DP4P STRUCTURE OF JVVNL 33KV 1250Amps 25kA 1 Sec VCBreaker CTRatio 200 100 55 33KV 1250Amps 25kA 1 Sec VCBreaker CTRatio 100 50 55 2 x 3150KVA 33KV 0433 KV OUTDOOR PLINTH MTD.

The materials used in the DP structure are. The un tensioned reinforcement as indicated in the drawings should be held in position by the use of stirrups which should go round all the wires. The quantity of concrete at the rate of 05 cum for DP.

Tenders are to be submitted online in electronic format on website httpeprocrajasthangovin. C Floodlighting Units 22. 33 KV LINE i Provision at DP.


Three Phase Two Pole Structure Installation Rs 180000 Unit Yash Electrotech Id 23035074897


Drawings For Steel Tubular Poles Bhutan Power Corporation Limited


33 Kv Line Dp Youtube


Design Of 33kv Switchyard Equipment Sld And Layout For Small Hydro Power Plant Eep


2


Mv Three Phase H Pole Transformer Structure 11kv And 33kv Thousands Of Free Autocad Drawings


Century Extrusions Product Range Hardware For Power T D


Century Extrusions Product Range Hardware For Power T D